Chemicals that are considered peroxide-forming are listed below. Containers of these chemicals must be dated when opened even if the chemicals contain inhibitors to retard peroxide formation.
It is a good practice to routinely test peroxidizable solvents for the presence of peroxides prior to their concentration or distillation. Peroxide Test strips can be purchased from VWR.
Group A: Chemicals that form explosive levels of peroxides without concentration. Date when received and when opened. Severe peroxide hazard after prolonged storage, especially after exposure to air. All have been responsible for fatalities. Test for peroxide formation before using, and discard 3 months after opening. Discard after storage for 12 months without opening.
| Butadiene | Isopropyl ether | Sodium amide |
| Chloroprene* | Potassium amide | Tetrafluoroethylene* |
| Divinyl acetylene | Potassium Metal | Vinylidine chloride |
Group B: Peroxide hazard upon concentration. Test for peroxide formation before distillation or evaporation. Date when opened, and discard within 1 year after opening.
| Acetal | Dicyclopentadiene | 2-Pentanol |
| Acetaldehyde | Diethylene glycol dimethyl-ether (diglyme) | 4-Penten-1-ol |
| Benzyl alcohol | Diethyl ether | 1-Phenylethanol |
| 2-Butanol Dioxanes | Ethylene glycol ether acetates (cellosolves) | 2-Phenylethanol |
| Chlorofluoroethylene | Furan | Tetrahydrofuran |
| Cumene (isopropylbenzene) | 4-Heptanol | Tetrahydronapthelene |
| Cyclohexene | 2-Hexanol | Vinyl ethers |
| 2-Cyclohexene-1-ol | Methyl acetylene | Other secondary alcohols |
| Cyclopentene | 3-Methyl-1-Butanol | |
| Decahydronapthaline (decalin) | Methyl-isobutyl ketone | |
| Diacetylene (butadiyne) | 4-Methyl-2-pentanol |
Group C: Chemicals that are hazardous due to peroxide initiation of autopolymerization. The peroxide forming potential increases for liquids of this group such that these materials should be considered a peroxide hazard. Test for peroxide formation before use, date when opened, and discard liquids after 6 months; discard gases after one year.
| Chlorobutadiene | Styrene | Vinyl acetate |
| Chloroprene | Tetrafluoroethylene | Vinyl chloride |
| Chlorotrifluoroethylene | Vinyl acetylene | Vinyldiene chloride |
| Vinyl pyridine |
*liquid monomer
Chemicals that decompose into peroxides present a serious hazard. After the peroxides form they may dry in the threads on the container's top or they may become concentrated if the chemical is distilled. Dry or concentrated peroxides formed in this manner are highly explosive and have caused serious explosions in laboratories.
All storage containers of chemicals that may form peroxides must be labeled with the date the container was opened. Laboratory personnel are responsible for dating containers when they are first opened.
Reference:
Peroxides and Peroxide Forming Compounds, Donald Clark, Journal of Chemical Health and safety, September/October 2001, 12-18.